D41B0220 - F41515 Multi-Meter Readings
Parameter Name | Data Item | Data Type | Req/Opt | I/O/Both |
---|---|---|---|---|
szMeterNumber | METN | char | NONE | NONE |
Identifies the meter. | ||||
mnIdentifierShortItem | ITM | MATH_NUMERIC | NONE | NONE |
An inventory item number. The system provides three separate item numbers plus an extensive cross-reference capability to other item
| ||||
szCostCenter | MCU | char | NONE | NONE |
An alphanumeric code that identifies a separate entity within a business for which you want to track costs. For example, a business unit
| ||||
szTankID | TKID | char | NONE | NONE |
An 8-character field identifying the tank as defined on the Branch/Plant Constants form. | ||||
mnUnitsPreviousTotalThroug | PPRR | MATH_NUMERIC | NONE | NONE |
The Quantity of product that has flowed through the meter since the last meter reading reconciliation. | ||||
mnUnitsNewTotalThroughputQ | PNCR | MATH_NUMERIC | NONE | NONE |
The closing reading of the meter at the date and time specified by the user.
This indicates the quantity of product that has flowed through the
| ||||
mnThroughputSinceLastRec | TTRE | MATH_NUMERIC | NONE | NONE |
The calculated volume that has passed through the meter since the last meter reading. | ||||
szUnitofMeasure10 | BUM0 | char | NONE | NONE |
A user defined code (system 00, type UM) that identifies the unit of measurement for pressure, volume, weight, diameter, or height. | ||||
mnVolumeAmbientInInventory | AMBI | MATH_NUMERIC | NONE | NONE |
The ambient quantity (prior to conversion to standard volume) which has been converted to the inventory unit of measure for that item. | ||||
szUnitofMeasureAmbientVolu | AMBU | char | NONE | NONE |
A user defined code (system 00, type UM) that identifies the unit of measurement for pressure, volume, weight, diameter, or height. | ||||
jdDateNewClosingReading | NRDJ | JDEDATE | NONE | NONE |
The date of the new closing reading. | ||||
mnTimeRead | RDTM | MATH_NUMERIC | NONE | NONE |
The time when the readings were performed. Enter the time in either HHMMSS or HH:MM:SS format. If you leave this field blank, the system
| ||||
cReconciliationStatus | RECS | char | NONE | NONE |
Identifies whether the reading has been reconciled. Valid values are:
Y The record has been fully reconciled.
N The record has not been
| ||||
cMeterStatus | METS | char | NONE | NONE |
Indicates whether the meter is active (A) or inactive (I). A meter must have an active status for reconciliation. You cannot enter a reading for
| ||||
cTemperatureCompensatedYN | TMCP | char | NONE | NONE |
Indicates whether the throughput volume is already at the standard temperature and a temperature conversion is required. Valid values
| ||||
mnReconciliationStatusLast | LRST | MATH_NUMERIC | NONE | NONE |
Identifies the current status in the reconciliation process. Entries in this field are User Defined Codes (UDCs).
Important note: Set up your
| ||||
mnReconciliationStatusNxt | NRST | MATH_NUMERIC | NONE | NONE |
Identifies the next status in the reconciliation process.
Important Note: Set up your Reconciliation Status - Next codes sequentially in the
| ||||
jdThroughputReconciledDate | THDT | JDEDATE | NONE | NONE |
The date a transaction is throughput reconciled. This is updated in the Update Throughput Operations process. | ||||
cMeterCorrectionFlag | MCYN | char | NONE | NONE |
When Y displays, this record is a meter correction | ||||
cProcessingMode | EV01 | char | NONE | NONE |
An option that specifies the type of processing for an event. | ||||
szDataItem | DTAI | char | NONE | NONE |
A code that identifies and defines a unit of information. It is an alphanumeric code up to 8 characters long that does not allow blanks or
| ||||
cSuppressErrorMessages | EV01 | char | NONE | NONE |
An option that specifies the type of processing for an event. | ||||
cErrorCode | ERRC | char | NONE | NONE |
This error code indicates if any errors occurred during the creation of the Trip Document Detail (F4914) records by the Delivery Document
|
None |
None |