VerifyAndGetMeterMaster

F41506 Verify And Get Meter Master

Master Business Function

Object Name: N41B0150

Parent DLL: CLOG

Location: Client/Server

Language: NER

Data Structure

D41B0150 - F41506 Verify And Get Meter Master

Parameter NameData ItemData TypeReq/OptI/O/Both
szCostCenterMCUcharNONENONE

An alphanumeric code that identifies a separate entity within a business for which you want to track costs. For example, a business unit 
might be a warehouse location, job, project, work center, branch, or plant. You can assign a business unit to a document, entity, or person for 
purposes of responsibility reporting. For example, the system provides reports of open accounts payable and accounts receivable by 
business unit to track equipment by responsible department. Business unit security might prevent you from viewing information about business units 
for which you have no authority.

szMeterNumberMETNcharNONENONE

Identifies the meter.

cMeterStatusMETScharNONENONE

Indicates whether the meter is active (A) or inactive (I). A meter must have an active status for reconciliation. You cannot enter a reading for 
an inactive meter

szSerialNumSER#charNONENONE

This field denotes the formal serial number of the meter for identification purposes.

szDescription001DL01charNONENONE

A user defined name or remark.

mnIdentifierShortItemITMMATH_NUMERICNONENONE

An inventory item number. The system provides three separate item numbers plus an extensive cross-reference capability to other item 
numbers (see data item XRT) to accommodate substitute item numbers, replacements, bar codes, customer numbers, supplier numbers, and 
so forth. The item numbers are as follows:   o Item Number (short) - An eight-digit, computer-assigned item number     o 2nd Item Number - The 
25-digit, free-form, user defined alphanumeric item number     o 3rd Item Number - Another 25-digit, free-form, user defined alphanumeric item 
number

mnItemNumberLastITMLMATH_NUMERICNONENONE

The item number of the product that previously occupied this area or location.

mnMaximumMeterReadingMXRDMATH_NUMERICNONENONE

The largest reading on the meter before it rolls back to one. If you leave this field blank, the system uses the value assigned in the data 
dictionary for this field

mnMeterUnitsMTUNMATH_NUMERICNONENONE

Designates the number of meter units used to calculate the quantity that passes through the meter. Meter units can differ from the units used 
to calculate volume or weight. For example, one meter unit can equal three actual volumetric units.

szUnitofMeasure1BUM1charNONENONE

A user defined code (system 00, type UM) that identifies the unit of measurement for pressure, volume, weight, diameter, or height. Note that 
for all volume or weight units of measure, a V or W (respectively) must be entered in the first position of the special handling field on the UDC 
table.

cTemperatureCompensatedYNTMCPcharNONENONE

Indicates whether the throughput volume is already at the standard temperature and a temperature conversion is required. Valid values 
are:    Y  Yes. You may also use 1.     N  No. You may also use 0.

cProcessControlSystemIntePCSIcharNONENONE

Indicates whether the product is being loaded via a loading rack (gantry). Valid values are:    Y  Loading rack interface in place. You may 
also use 1.    N  Loading rack interface not in place. You may also use 0.

mnTotalThroughputSinceLastTTHRMATH_NUMERICNONENONE

Enter a valid number and the unit of measure in these fields. If you leave the first field blank, the system uses zero. You can enter values in 
these fields only during initial meter setup. After you have set up the meter, the total throughput is a rolling figure from the Meter Master table 
(F41506). As the system calculates volumes from closing readings, it adds them to the prior total to obtain a current figure for this record. If you 
change the date in the Date Last Calibrated field, the system clears this field.

szUnitofMeasure10BUM0charNONENONE

A user defined code (system 00, type UM) that identifies the unit of measurement for pressure, volume, weight, diameter, or height.

jdDateLastCalibratedDLCAJDEDATENONENONE

The last date that the meter flow was tested and calibrated. Whenever this date is changed, the system resets the entry in the Throughput 
Since Last Calibration field to zero.

jdDateInstalledMeterNDTEJDEDATENONENONE

The date the meter was installed.

cYesOrNoEntry1YN01charNONENONE

The Yes or No Entry field is a single character entry field for yes or no responses on prompt screens.

jdUserReservedDateURDTJDEDATENONENONE

This is a 6 position code that is reserved for the user.  JDE does not currently use this field and will not utilize this field in the future.

mnUserReservedAmountURATMATH_NUMERICNONENONE

This is a 15 position code that is reserved for the user.  JDE does not currently use this field and will not utilize this field in the future.

szUserReservedCodeURCDcharNONENONE

This is a 2 position code that is reserved for the user.  JDE does not currently use this field and will not utilize this field in the future.

mnUserReservedNumberURABMATH_NUMERICNONENONE

This is a 8 position code that is reserved for the user.  JDE does not currently use this field and will not utilize this field in the future.

szUserReservedReferenceURRFcharNONENONE

A 15-position reference that is reserved for the user.  J.D. Edwards does not currently use this field and does not plan to use it in the future.

cSuppressErrorMessagesEV01charNONENONE

An option that specifies the type of processing for an event.

szErrorMessageIDDTAIcharNONENONE

A code that identifies and defines a unit of information. It is an alphanumeric code up to 8 characters long that does not allow blanks or 
special characters such as %, &, or +. You create new data items using system codes 55-59. You cannot change the alias.

Related Functions

None

Related Tables

F41506 Meter Master