DF30L199A - DFM SOE Functional Server
| Parameter Name | Data Item | Data Type | Req/Opt | I/O/Both |
|---|---|---|---|---|
| szSessionId_CCHN | CCHN | char | OPT | NONE |
A unique session ID based on Process ID, Transaction ID, and Job Number. | ||||
| mnShortItemDFM_DFITM | DFITM | MATH_NUMERIC | OPT | NONE |
A number that identifies the item. The system provides three separate item numbers to alternative item numbers. The three types of item
| ||||
| szDFBranchPlant_DFMCU | DFMCU | char | OPT | NONE |
Identifies the branch/plant that accompanies a component. | ||||
| mnProcessId_PROID | PROID | MATH_NUMERIC | OPT | NONE |
A unique number that is used to identify a Process within the Demand Flow Manufacturing system. | ||||
| cSuppressErrorMessage_SUPPS | SUPPS | char | OPT | NONE |
A flag indicating whether or not runtime error messaging will occur when an error message is issued from a business function.
0 = allow
| ||||
| szErrorMessageID_DTAI | DTAI | char | OPT | NONE |
A code that identifies and defines a unit of information. It is an alphanumeric code up to 8 characters long that does not allow blanks or
| ||||
| mnScenarioId_FSCID | FSCID | MATH_NUMERIC | OPT | NONE |
A unique number that is used to identify a scenario within the Demand Flow Manufacturing system. | ||||
| szItemDescription_DESC | DESC | char | OPT | NONE |
A description, remark, name, or address. | ||||
| szProcessName_PRNA | PRNA | char | OPT | NONE |
A unique Process name that is used to identify a Process within the Demand Flow Manufacturing system. | ||||
| mnRepPartNumber_RPITM | RPITM | MATH_NUMERIC | OPT | NONE |
Part number used to represent a group of parts. | ||||
| szRepPartDescription_DESC | DESC | char | OPT | NONE |
A description, remark, name, or address. | ||||
| mnStandardTaskId_STSKID | STSKID | MATH_NUMERIC | OPT | NONE |
A unique number that is used to identify a Standard Task within the Demand Flow Manufacturing system. | ||||
| szTaskName_TSKNAME | TSKNAME | char | OPT | NONE |
Name that is used to identify a Standard Task or Task within the Demand Flow Manufacturing system.
In Sequence of Event, if this field is
| ||||
| mnRepeatQuantity_RPQTY | RPQTY | MATH_NUMERIC | OPT | NONE |
A value that indicates the number of times a task will be repeated. The default value is 1.
In Sequence of Events, if this field is changed then
| ||||
| szInternalExternal_INTEXT | INTEXT | char | OPT | NONE |
A user defined code (F30L/IE) that determines if the machine setup is internal or external. Valid values are:
' '
Blank
I
Internal
X
External
In
| ||||
| mnFeederPathID_FDPID | FDPID | MATH_NUMERIC | OPT | NONE |
A number that uniquely identifies a Feeder Path.
In Sequence of Event, if this field is changed then the changes will not be carried over to
| ||||
| mnFeederPartNumber_FDITM | FDITM | MATH_NUMERIC | OPT | NONE |
Part number used in the feeder process which goes to the assembly of the final product.
In Sequence of Event, if this field is changed then
| ||||
| szFeederPartDescription_DESC | DESC | char | OPT | NONE |
A description, remark, name, or address. | ||||
| szFeederBranch_FDMCU | FDMCU | char | OPT | NONE |
Branch Plant where the feeder activity takes place.
In Sequence of Events, if this field is changed then the changes will not be carried over
| ||||
| szComponentsConsumed_CMCONS | CMCONS | char | OPT | NONE |
A property that indicates the task consumes components. Values are:
Y
Yes
N
No. In Sequence of Events, if the task consumes
| ||||
| szSSOEComparison_SSOECMP | SSOECMP | char | OPT | NONE |
A user defined code (F30L/SO) that indicates if the SSOE task has been modified. Values are:
U
Task for the SSOE has not been modified.
| ||||
| szFeederFlag_FEFG | FEFG | char | OPT | NONE |
A code to indicate a feeder path on a process. A 'Yes' indicates that a feeder path or a number of feeder paths are associated with the
| ||||
| szOverlapPrevSeqProperty_OPSP | OPSP | char | OPT | NONE |
A property that indicates the Sequence of Event Task overlaps the previous task for the current Sequence of Events. In other words, the
| ||||
| mnStandardSeqEventsID_SSOEID | SSOEID | MATH_NUMERIC | OPT | NONE |
A value that uniquely identifies a SSOE. | ||||
| szSSOEName_SSOEN | SSOEN | char | OPT | NONE |
A unique name that is used to identify a Standard Sequence of events within the Demand Flow Manufacturing system. | ||||
| szStandardTaskProperty_STSKPRP | STSKPRP | char | OPT | NONE |
A property that indicates that the task is a Standard Task. Valid values are: Y Yes, this is a standard task. N No, this is not a standard task. | ||||
| szTaskShortDescription_DESC | DESC | char | OPT | NONE |
A description, remark, name, or address. | ||||
| szTaskDescription_TSKDSC | TSKDSC | char | OPT | NONE |
Description of a Task that describes the work steps that occur repeatedly across multiple products and/or processes.
In Sequence of
| ||||
| szWorkType_WRKTY | WRKTY | char | OPT | NONE |
A user defined code (F30L/WT), which indicates the type of work being performed. Valid Values are:
RQ - Required - Required
| ||||
| szValueAdded_VALADD | VALADD | char | OPT | NONE |
A property, which indicates if the task being performed adds value to the end product. Valid values are:
Y - Yes
N - No
In Sequence of
| ||||
| mnResourceID_DFRID | DFRID | MATH_NUMERIC | OPT | NONE |
A unique value that indicates the Resource ID. In Sequence of Events, if this field is changed then the changes will be carried over to the
| ||||
| szResourceName_DFRDESC | DFRDESC | char | OPT | NONE |
A name that describes a resource. This name must be unique within the scenario. In Sequence of Events, if this field is changed, then the
| ||||
| szResourceType_DFRT | DFRT | char | OPT | NONE |
A value that indicates the type of resource. | ||||
| mnStaticQuantity_STQTY | STQTY | MATH_NUMERIC | OPT | NONE |
When work content is performed once every "n" times in the process of manufacturing a product, you define a Static Quantity. Static
| ||||
| mnStandardTaskTime_STSKTIME | STSKTIME | MATH_NUMERIC | OPT | NONE |
Amount of time required to perform the work of the task.
In Sequence of Events, if this field is changed then the changes will not be carried
| ||||
| szTQCDescription_TQCDESC | TQCDESC | char | OPT | NONE |
Instructions used to describe how the TQC work is performed.
In Sequence of Event, if this field is changed then the changes will not be
| ||||
| szTQCCriteria_TQCCRT | TQCCRT | char | OPT | NONE |
Value which indicates the criteria for quality control of the work being performed. Value will default to Failsafe. Valid Values are:
FS -
| ||||
| cTimeUOM_TIMEUOM | TIMEUOM | char | OPT | NONE |
A user defined code (F30L/WC) that defines what unit of measure in which the time is defined; such as, Hour, Minutes or Seconds. Valid
| ||||
| szItemNoUnknownFormat_DFUITM | DFUITM | char | OPT | NONE |
A number that the system assigns to an item. It can be in short, long or third item number format. | ||||
| mnSequenceNumber_DFSEQ | DFSEQ | MATH_NUMERIC | OPT | NONE |
A value that indicates the sequence number when adding sequence of events or creating a sequence for a daily plan. The default is 10.00.
| ||||
| mnSeqOfEventId_SOEID | SOEID | MATH_NUMERIC | OPT | NONE |
A unique number that is used to identify a Sequence of Events within the Demand Flow Manufacturing system. | ||||
| mnSOELineId_SOELID | SOELID | MATH_NUMERIC | OPT | NONE |
Used as a part of a key to identify a task line on a SOE/SSOE. | ||||
| mnTotalMachineTime_STSKTIME | STSKTIME | MATH_NUMERIC | OPT | NONE |
Amount of time required to perform the work of the task.
In Sequence of Events, if this field is changed then the changes will not be carried
| ||||
| mnTotalLaborTime_STSKTIME | STSKTIME | MATH_NUMERIC | OPT | NONE |
Amount of time required to perform the work of the task.
In Sequence of Events, if this field is changed then the changes will not be carried
| ||||
| cErrorCode_ERRC | ERRC | char | OPT | NONE |
This error code indicates if any errors occurred during the creation of the Trip Document Detail (F4914) records by the Delivery Document
| ||||
| szRepPartUnknownFormat_DFUITM | DFUITM | char | OPT | NONE |
A number that the system assigns to an item. It can be in short, long or third item number format. | ||||
| mnShortItemDFMCopy_DFITM | DFITM | MATH_NUMERIC | OPT | NONE |
A number that identifies the item. The system provides three separate item numbers to alternative item numbers. The three types of item
| ||||
| szDFBranchPlantCopy_DFMCU | DFMCU | char | OPT | NONE |
Identifies the branch/plant that accompanies a component. | ||||
| mnProcessIdCopy_PROID | PROID | MATH_NUMERIC | OPT | NONE |
A unique number that is used to identify a Process within the Demand Flow Manufacturing system. | ||||
| szPathName_PHNA | PHNA | char | OPT | NONE |
The name of a Path that identifies a Path (Product Sync, Rework, Feeder or Option Path) in the Path Master Table (FF30L702).
In Sequence
| ||||
| szFeederPart_DFUITM | DFUITM | char | OPT | NONE |
A number that the system assigns to an item. It can be in short, long or third item number format. | ||||
| mnTaskTimeInSec_STSKTIME | STSKTIME | MATH_NUMERIC | OPT | NONE |
Amount of time required to perform the work of the task.
In Sequence of Events, if this field is changed then the changes will not be carried
| ||||
| mnPathID_PHID | PHID | MATH_NUMERIC | OPT | NONE |
A number that uniquely identifies a Path (Product Synchronization, Rework, Feeder or Option Path) in the Path Master Table (FF30L702). | ||||
| mnTotalSOETimeInSec_STSKTIME | STSKTIME | MATH_NUMERIC | OPT | NONE |
Amount of time required to perform the work of the task.
In Sequence of Events, if this field is changed then the changes will not be carried
| ||||
| szRecordActionCode_CACTN | CACTN | char | OPT | NONE |
A code that indicates the activity you want to perform. Valid codes:
o Get - Retrieve the cache element
o Add - Add a cache element
o
| ||||
| mnSequenceInterval_DFSEQ | DFSEQ | MATH_NUMERIC | OPT | NONE |
A value that indicates the sequence number when adding sequence of events or creating a sequence for a daily plan. The default is 10.00.
| ||||
| szPSyncPathName_PHNA | PHNA | char | OPT | NONE |
The name of a Path that identifies a Path (Product Sync, Rework, Feeder or Option Path) in the Path Master Table (FF30L702).
In Sequence
| ||||
| szApplicationID_PID | PID | char | OPT | NONE |
The number that identifies the batch or interactive program (batch or interactive object). For example, the number of the Sales Order Entry
| ||||
| jdCompEffectiveDate_CMEFT | CMEFT | JDEDATE | OPT | NONE |
The Effective Date indicates when the components are to be used.
In Sequence of Events, if the effective date changes, then the change
| ||||
| mnNewSOELineId_SOELID | SOELID | MATH_NUMERIC | OPT | NONE |
Used as a part of a key to identify a task line on a SOE/SSOE. | ||||
| mnNewSequenceNumber_DFSEQ | DFSEQ | MATH_NUMERIC | OPT | NONE |
A value that indicates the sequence number when adding sequence of events or creating a sequence for a daily plan. The default is 10.00.
| ||||
| None |
| None |