DF30L199A - DFM SOE Functional Server
| Parameter Name | Data Item | Data Type | Req/Opt | I/O/Both | 
|---|---|---|---|---|
| szSessionId_CCHN | CCHN | char | OPT | NONE | 
A unique session ID based on Process ID, Transaction ID, and Job Number.  | ||||
| mnShortItemDFM_DFITM | DFITM | MATH_NUMERIC | OPT | NONE | 
A number that identifies the item. The system provides three separate item numbers to alternative item numbers. The three types of item 
  | ||||
| szDFBranchPlant_DFMCU | DFMCU | char | OPT | NONE | 
Identifies the branch/plant that accompanies a component.  | ||||
| mnProcessId_PROID | PROID | MATH_NUMERIC | OPT | NONE | 
A unique number that is used to identify a Process within the Demand Flow Manufacturing system.  | ||||
| cSuppressErrorMessage_SUPPS | SUPPS | char | OPT | NONE | 
A flag indicating whether or not runtime error messaging will occur when an error message is issued from a business function.
       0 = allow 
  | ||||
| szErrorMessageID_DTAI | DTAI | char | OPT | NONE | 
A code that identifies and defines a unit of information. It is an alphanumeric code up to 8 characters long that does not allow blanks or 
  | ||||
| mnScenarioId_FSCID | FSCID | MATH_NUMERIC | OPT | NONE | 
A unique number that is used to identify a scenario within the Demand Flow Manufacturing system.  | ||||
| szItemDescription_DESC | DESC | char | OPT | NONE | 
A description, remark, name, or address.  | ||||
| szProcessName_PRNA | PRNA | char | OPT | NONE | 
A unique Process name that is used to identify a Process within the Demand Flow Manufacturing system.  | ||||
| mnRepPartNumber_RPITM | RPITM | MATH_NUMERIC | OPT | NONE | 
Part number used to represent a group of parts.  | ||||
| szRepPartDescription_DESC | DESC | char | OPT | NONE | 
A description, remark, name, or address.  | ||||
| mnStandardTaskId_STSKID | STSKID | MATH_NUMERIC | OPT | NONE | 
A unique number that is used to identify a Standard Task within the Demand Flow Manufacturing system.  | ||||
| szTaskName_TSKNAME | TSKNAME | char | OPT | NONE | 
Name that is used to identify a Standard Task or Task within the Demand Flow Manufacturing system.
In Sequence of Event, if this field is 
  | ||||
| mnRepeatQuantity_RPQTY | RPQTY | MATH_NUMERIC | OPT | NONE | 
A value that indicates the number of times a task will be repeated. The default value is 1.
In Sequence of Events, if this field is changed then 
  | ||||
| szInternalExternal_INTEXT | INTEXT | char | OPT | NONE | 
A user defined code (F30L/IE) that determines if the machine setup is internal or external.  Valid values are:
' '
Blank
I
Internal
  
X
External
In 
  | ||||
| mnFeederPathID_FDPID | FDPID | MATH_NUMERIC | OPT | NONE | 
A number that uniquely identifies a Feeder Path. 
In Sequence of Event, if this field is changed then the changes will not be carried over to 
  | ||||
| mnFeederPartNumber_FDITM | FDITM | MATH_NUMERIC | OPT | NONE | 
Part number used in the feeder process which goes to the assembly of the final product.  
In Sequence of Event, if this field is changed then 
  | ||||
| szFeederPartDescription_DESC | DESC | char | OPT | NONE | 
A description, remark, name, or address.  | ||||
| szFeederBranch_FDMCU | FDMCU | char | OPT | NONE | 
Branch Plant where the feeder activity takes place.
In Sequence of Events, if this field is changed then the changes will not be carried over 
  | ||||
| szComponentsConsumed_CMCONS | CMCONS | char | OPT | NONE | 
A property that indicates the task consumes components.  Values are:
Y
Yes 
N
No.  In Sequence of Events, if the task consumes 
  | ||||
| szSSOEComparison_SSOECMP | SSOECMP | char | OPT | NONE | 
A user defined code (F30L/SO) that indicates if the SSOE task has been modified.  Values are: 
U
Task for the SSOE has not been modified. 
  | ||||
| szFeederFlag_FEFG | FEFG | char | OPT | NONE | 
A code to indicate a feeder path on a process.  A 'Yes' indicates that a feeder path or a number of feeder paths are associated with the 
  | ||||
| szOverlapPrevSeqProperty_OPSP | OPSP | char | OPT | NONE | 
A property that indicates the Sequence of Event Task overlaps the previous task for the current Sequence of Events.  In other words, the 
  | ||||
| mnStandardSeqEventsID_SSOEID | SSOEID | MATH_NUMERIC | OPT | NONE | 
A value that uniquely identifies a SSOE.  | ||||
| szSSOEName_SSOEN | SSOEN | char | OPT | NONE | 
A unique name that is used to identify a Standard Sequence of events within the Demand Flow Manufacturing system.  | ||||
| szStandardTaskProperty_STSKPRP | STSKPRP | char | OPT | NONE | 
A property that indicates that the task is a Standard Task. Valid values are: Y Yes, this is a standard task. N No, this is not a standard task.  | ||||
| szTaskShortDescription_DESC | DESC | char | OPT | NONE | 
A description, remark, name, or address.  | ||||
| szTaskDescription_TSKDSC | TSKDSC | char | OPT | NONE | 
Description of a Task that describes the work steps that occur repeatedly across multiple products and/or processes.
In Sequence of 
  | ||||
| szWorkType_WRKTY | WRKTY | char | OPT | NONE | 
A user defined code (F30L/WT), which indicates the type of work being performed.  Valid Values are:
  RQ - Required - Required 
  | ||||
| szValueAdded_VALADD | VALADD | char | OPT | NONE | 
A property, which indicates if the task being performed adds value to the end product.  Valid values are:
  Y - Yes
  N - No
In Sequence of 
  | ||||
| mnResourceID_DFRID | DFRID | MATH_NUMERIC | OPT | NONE | 
A unique value that indicates the Resource ID.  In Sequence of Events, if this field is changed then the changes will be carried over to the 
  | ||||
| szResourceName_DFRDESC | DFRDESC | char | OPT | NONE | 
A name that describes a resource.  This name must be unique within the scenario.  In Sequence of Events, if this field is changed, then the 
  | ||||
| szResourceType_DFRT | DFRT | char | OPT | NONE | 
A value that indicates the type of resource.  | ||||
| mnStaticQuantity_STQTY | STQTY | MATH_NUMERIC | OPT | NONE | 
When work content is performed once every "n" times in the process of manufacturing a product, you define a Static Quantity.  Static 
  | ||||
| mnStandardTaskTime_STSKTIME | STSKTIME | MATH_NUMERIC | OPT | NONE | 
Amount of time required to perform the work of the task. 
In Sequence of Events, if this field is changed then the changes will not be carried 
  | ||||
| szTQCDescription_TQCDESC | TQCDESC | char | OPT | NONE | 
Instructions used to describe how the TQC work is performed.
In Sequence of Event, if this field is changed then the changes will not be 
  | ||||
| szTQCCriteria_TQCCRT | TQCCRT | char | OPT | NONE | 
Value which indicates the criteria for quality control of the work being performed.  Value will default to Failsafe.  Valid Values are:
  FS - 
  | ||||
| cTimeUOM_TIMEUOM | TIMEUOM | char | OPT | NONE | 
A user defined code (F30L/WC) that defines what unit of measure in which the time is defined; such as, Hour, Minutes or Seconds.  Valid 
  | ||||
| szItemNoUnknownFormat_DFUITM | DFUITM | char | OPT | NONE | 
A number that the system assigns to an item. It can be in short, long or third item number format.  | ||||
| mnSequenceNumber_DFSEQ | DFSEQ | MATH_NUMERIC | OPT | NONE | 
A value that indicates the sequence number when adding sequence of events or creating a sequence for a daily plan. The default is 10.00.  
  | ||||
| mnSeqOfEventId_SOEID | SOEID | MATH_NUMERIC | OPT | NONE | 
A unique number that is used to identify a Sequence of Events within the Demand Flow Manufacturing system.  | ||||
| mnSOELineId_SOELID | SOELID | MATH_NUMERIC | OPT | NONE | 
Used as a part of a key to identify a task line on a SOE/SSOE.  | ||||
| mnTotalMachineTime_STSKTIME | STSKTIME | MATH_NUMERIC | OPT | NONE | 
Amount of time required to perform the work of the task. 
In Sequence of Events, if this field is changed then the changes will not be carried 
  | ||||
| mnTotalLaborTime_STSKTIME | STSKTIME | MATH_NUMERIC | OPT | NONE | 
Amount of time required to perform the work of the task. 
In Sequence of Events, if this field is changed then the changes will not be carried 
  | ||||
| cErrorCode_ERRC | ERRC | char | OPT | NONE | 
This error code indicates if any errors occurred during the creation of the Trip Document Detail (F4914) records by the Delivery Document 
  | ||||
| szRepPartUnknownFormat_DFUITM | DFUITM | char | OPT | NONE | 
A number that the system assigns to an item. It can be in short, long or third item number format.  | ||||
| mnShortItemDFMCopy_DFITM | DFITM | MATH_NUMERIC | OPT | NONE | 
A number that identifies the item. The system provides three separate item numbers to alternative item numbers. The three types of item 
  | ||||
| szDFBranchPlantCopy_DFMCU | DFMCU | char | OPT | NONE | 
Identifies the branch/plant that accompanies a component.  | ||||
| mnProcessIdCopy_PROID | PROID | MATH_NUMERIC | OPT | NONE | 
A unique number that is used to identify a Process within the Demand Flow Manufacturing system.  | ||||
| szPathName_PHNA | PHNA | char | OPT | NONE | 
The name of a Path that identifies a Path (Product Sync, Rework, Feeder or Option Path) in the Path Master Table (FF30L702). 
In Sequence 
  | ||||
| szFeederPart_DFUITM | DFUITM | char | OPT | NONE | 
A number that the system assigns to an item. It can be in short, long or third item number format.  | ||||
| mnTaskTimeInSec_STSKTIME | STSKTIME | MATH_NUMERIC | OPT | NONE | 
Amount of time required to perform the work of the task. 
In Sequence of Events, if this field is changed then the changes will not be carried 
  | ||||
| mnPathID_PHID | PHID | MATH_NUMERIC | OPT | NONE | 
A number that uniquely identifies a Path (Product Synchronization, Rework, Feeder or Option Path) in the Path Master Table (FF30L702).  | ||||
| mnTotalSOETimeInSec_STSKTIME | STSKTIME | MATH_NUMERIC | OPT | NONE | 
Amount of time required to perform the work of the task. 
In Sequence of Events, if this field is changed then the changes will not be carried 
  | ||||
| szRecordActionCode_CACTN | CACTN | char | OPT | NONE | 
A code that indicates the activity you want to perform. Valid codes:
    o Get - Retrieve the cache element
    o Add - Add a cache element
    o 
  | ||||
| mnSequenceInterval_DFSEQ | DFSEQ | MATH_NUMERIC | OPT | NONE | 
A value that indicates the sequence number when adding sequence of events or creating a sequence for a daily plan. The default is 10.00.  
  | ||||
| szPSyncPathName_PHNA | PHNA | char | OPT | NONE | 
The name of a Path that identifies a Path (Product Sync, Rework, Feeder or Option Path) in the Path Master Table (FF30L702). 
In Sequence 
  | ||||
| szApplicationID_PID | PID | char | OPT | NONE | 
The number that identifies the batch or interactive program (batch or interactive object). For example, the number of the Sales Order Entry 
  | ||||
| jdCompEffectiveDate_CMEFT | CMEFT | JDEDATE | OPT | NONE | 
The Effective Date indicates when the components are to be used.  
In Sequence of Events, if the effective date changes, then the change 
  | ||||
| mnNewSOELineId_SOELID | SOELID | MATH_NUMERIC | OPT | NONE | 
Used as a part of a key to identify a task line on a SOE/SSOE.  | ||||
| mnNewSequenceNumber_DFSEQ | DFSEQ | MATH_NUMERIC | OPT | NONE | 
A value that indicates the sequence number when adding sequence of events or creating a sequence for a daily plan. The default is 10.00.  
  | ||||
| None | 
| None |