DF30L196A - FF30L110 DFM Standard SSOE Functional Server
| Parameter Name | Data Item | Data Type | Req/Opt | I/O/Both | 
|---|---|---|---|---|
| cSuppressErrorMessage | SUPPS | char | OPT | NONE | 
A flag indicating whether or not runtime error messaging will occur when an error message is issued from a business function.
       0 = allow 
  | ||||
| szErrorMessageID | DTAI | char | OPT | NONE | 
A code that identifies and defines a unit of information. It is an alphanumeric code up to 8 characters long that does not allow blanks or 
  | ||||
| cErrorCode | ERRC | char | OPT | NONE | 
This error code indicates if any errors occurred during the creation of the Trip Document Detail (F4914) records by the Delivery Document 
  | ||||
| szSessionId | CCHN | char | OPT | NONE | 
A unique session ID based on Process ID, Transaction ID, and Job Number.  | ||||
| mnStandardSeqEventsID | SSOEID | MATH_NUMERIC | OPT | NONE | 
A value that uniquely identifies a SSOE.  | ||||
| mnSOELineId | SOELID | MATH_NUMERIC | OPT | NONE | 
Used as a part of a key to identify a task line on a SOE/SSOE.  | ||||
| mnScenarioId | FSCID | MATH_NUMERIC | OPT | NONE | 
A unique number that is used to identify a scenario within the Demand Flow Manufacturing system.  | ||||
| szSSOEName | SSOEN | char | OPT | NONE | 
A unique name that is used to identify a Standard Sequence of events within the Demand Flow Manufacturing system.  | ||||
| mnSequenceNumber | DFSEQ | MATH_NUMERIC | OPT | NONE | 
A value that indicates the sequence number when adding sequence of events or creating a sequence for a daily plan. The default is 10.00.  
  | ||||
| szStdSeqOfEventDescription | SSOEDESC | char | OPT | NONE | 
Description for the Standard Sequence of Events.  | ||||
| szOverlapPrevSeqProperty | OPSP | char | OPT | NONE | 
A property that indicates the Sequence of Event Task overlaps the previous task for the current Sequence of Events.  In other words, the 
  | ||||
| mnTaskId | STSKID | MATH_NUMERIC | OPT | NONE | 
A unique number that is used to identify a Standard Task within the Demand Flow Manufacturing system.  | ||||
| mnTaskRepitition | RPQTY | MATH_NUMERIC | OPT | NONE | 
A value that indicates the number of times a task will be repeated. The default value is 1.
In Sequence of Events, if this field is changed then 
  | ||||
| szInternalExternal | INTEXT | char | OPT | NONE | 
A user defined code (F30L/IE) that determines if the machine setup is internal or external.  Valid values are:
' '
Blank
I
Internal
  
X
External
In 
  | ||||
| szFeederFlag | FEFG | char | OPT | NONE | 
A code to indicate a feeder path on a process.  A 'Yes' indicates that a feeder path or a number of feeder paths are associated with the 
  | ||||
| mnFeederPathID | FDPID | MATH_NUMERIC | OPT | NONE | 
A number that uniquely identifies a Feeder Path. 
In Sequence of Event, if this field is changed then the changes will not be carried over to 
  | ||||
| mnFeederPartNumber | FDITM | MATH_NUMERIC | OPT | NONE | 
Part number used in the feeder process which goes to the assembly of the final product.  
In Sequence of Event, if this field is changed then 
  | ||||
| szStandardTaskProperty | STSKPRP | char | OPT | NONE | 
A property that indicates that the task is a Standard Task. Valid values are: Y Yes, this is a standard task. N No, this is not a standard task.  | ||||
| szStandardTaskName | TSKNAME | char | OPT | NONE | 
Name that is used to identify a Standard Task or Task within the Demand Flow Manufacturing system.
In Sequence of Event, if this field is 
  | ||||
| szDescription | DESC | char | OPT | NONE | 
A description, remark, name, or address.  | ||||
| szTaskDescription | TSKDSC | char | OPT | NONE | 
Description of a Task that describes the work steps that occur repeatedly across multiple products and/or processes.
In Sequence of 
  | ||||
| szWorkType | WRKTY | char | OPT | NONE | 
A user defined code (F30L/WT), which indicates the type of work being performed.  Valid Values are:
  RQ - Required - Required 
  | ||||
| szValueAdded | VALADD | char | OPT | NONE | 
A property, which indicates if the task being performed adds value to the end product.  Valid values are:
  Y - Yes
  N - No
In Sequence of 
  | ||||
| mnResourceID | DFRID | MATH_NUMERIC | OPT | NONE | 
A unique value that indicates the Resource ID.  In Sequence of Events, if this field is changed then the changes will be carried over to the 
  | ||||
| mnStaticQuantity | STQTY | MATH_NUMERIC | OPT | NONE | 
When work content is performed once every "n" times in the process of manufacturing a product, you define a Static Quantity.  Static 
  | ||||
| mnTaskTime | STSKTIME | MATH_NUMERIC | OPT | NONE | 
Amount of time required to perform the work of the task. 
In Sequence of Events, if this field is changed then the changes will not be carried 
  | ||||
| cTimeUOM | TIMEUOM | char | OPT | NONE | 
A user defined code (F30L/WC) that defines what unit of measure in which the time is defined; such as, Hour, Minutes or Seconds.  Valid 
  | ||||
| szTQCDescription | TQCDESC | char | OPT | NONE | 
Instructions used to describe how the TQC work is performed.
In Sequence of Event, if this field is changed then the changes will not be 
  | ||||
| szTQCCriteria | TQCCRT | char | OPT | NONE | 
Value which indicates the criteria for quality control of the work being performed.  Value will default to Failsafe.  Valid Values are:
  FS - 
  | ||||
| szResourceName | DFRDESC | char | OPT | NONE | 
A name that describes a resource.  This name must be unique within the scenario.  In Sequence of Events, if this field is changed, then the 
  | ||||
| szResourceType | DFRT | char | OPT | NONE | 
A value that indicates the type of resource.  | ||||
| szUserReservedCode | URCD | char | OPT | NONE | 
This is a 2 position code that is reserved for the user. JDE does not currently use this field and will not utilize this field in the future.  | ||||
| jdUserReservedDate | URDT | JDEDATE | OPT | NONE | 
This is a 6 position code that is reserved for the user. JDE does not currently use this field and will not utilize this field in the future.  | ||||
| mnUserReservedAmount | URAT | MATH_NUMERIC | OPT | NONE | 
This is a 15 position code that is reserved for the user. JDE does not currently use this field and will not utilize this field in the future.  | ||||
| szUserReservedReference | URRF | char | OPT | NONE | 
A 15-position reference that is reserved for the user. J.D. Edwards does not currently use this field and does not plan to use it in the future.  | ||||
| szTransactionOriginator | TORG | char | OPT | NONE | 
The person who originally entered the transaction.  | ||||
| szUserId | USER | char | OPT | NONE | 
The code that identifies a user profile.  | ||||
| szProgramId | PID | char | OPT | NONE | 
The number that identifies the batch or interactive program (batch or interactive object). For example, the number of the Sales Order Entry 
  | ||||
| szMachineKey | MKEY | char | OPT | NONE | 
The Location or Machine Key indicates the name of the machine on the network (server or workstation).  | ||||
| UniversalDateUpdated | UUPMJ | INVALID ITEM DATA TYPE: 55 | OPT | NONE | 
| mnUserReservedNumber | URAB | MATH_NUMERIC | OPT | NONE | 
This is a 8 position code that is reserved for the user. JDE does not currently use this field and will not utilize this field in the future.  | ||||
| mnSequenceInterval | DFSEQI | MATH_NUMERIC | OPT | NONE | 
A value that indicates the sequence interval when adding sequence of events or creating a sequence for a daily plan. The default is 10.00.  | ||||
| szPathName | PHNA | char | OPT | NONE | 
The name of a Path that identifies a Path (Product Sync, Rework, Feeder or Option Path) in the Path Master Table (FF30L702). 
In Sequence 
  | ||||
| cActionCode | ACTN | char | OPT | NONE | 
A code that specifies the action that is performed. Valid values are: A Add C Change  | ||||
| mnTotalLaborTime | STSKTIME | MATH_NUMERIC | OPT | NONE | 
Amount of time required to perform the work of the task. 
In Sequence of Events, if this field is changed then the changes will not be carried 
  | ||||
| mnTotalMachineTime | STSKTIME | MATH_NUMERIC | OPT | NONE | 
Amount of time required to perform the work of the task. 
In Sequence of Events, if this field is changed then the changes will not be carried 
  | ||||
| szFeederBranch | FDMCU | char | OPT | NONE | 
Branch Plant where the feeder activity takes place.
In Sequence of Events, if this field is changed then the changes will not be carried over 
  | ||||
| mnStartSequenceNumber | DFSEQ | MATH_NUMERIC | OPT | NONE | 
A value that indicates the sequence number when adding sequence of events or creating a sequence for a daily plan. The default is 10.00.  
  | ||||
| mnTaskTimeInSeconds | STSKTIME | MATH_NUMERIC | OPT | NONE | 
Amount of time required to perform the work of the task. 
In Sequence of Events, if this field is changed then the changes will not be carried 
  | ||||
| None | 