DF30L194A - Process FF30L110 Data - All Columns
Parameter Name | Data Item | Data Type | Req/Opt | I/O/Both |
---|---|---|---|---|
cSuppressErrorMessage | SUPPS | char | OPT | NONE |
A flag indicating whether or not runtime error messaging will occur when an error message is issued from a business function.
0 = allow
| ||||
cProcessEdit | PROE | char | OPT | NONE |
Internal Use Only. | ||||
cReturnHRequest | RHREQ | char | OPT | NONE |
Internal Use Only. | ||||
hRequestID | GENLNG | ID | OPT | NONE |
General purpose ID variable. | ||||
cActionCode | ACTN | char | OPT | NONE |
A code that specifies the action that is performed. Valid values are: A Add C Change | ||||
cIndexNumber | JDEINDX | char | OPT | NONE |
Use indexes to find specific records and sort records faster. Table indexes are like tabs in a card file. Each index is comprised of one or
| ||||
mnNumberKeys | NKEYS | MATH_NUMERIC | OPT | NONE |
The number of keys in an index that will be used to retrieve, delete, or update a record. | ||||
mnStandardSeqEventsID | SSOEID | MATH_NUMERIC | OPT | NONE |
A value that uniquely identifies a SSOE. | ||||
mnSOELineId | SOELID | MATH_NUMERIC | OPT | NONE |
Used as a part of a key to identify a task line on a SOE/SSOE. | ||||
mnSequenceNumber | DFSEQ | MATH_NUMERIC | OPT | NONE |
A value that indicates the sequence number when adding sequence of events or creating a sequence for a daily plan. The default is 10.00.
| ||||
mnScenarioId | FSCID | MATH_NUMERIC | OPT | NONE |
A unique number that is used to identify a scenario within the Demand Flow Manufacturing system. | ||||
szSSOEName | SSOEN | char | OPT | NONE |
A unique name that is used to identify a Standard Sequence of events within the Demand Flow Manufacturing system. | ||||
szStdSeqOfEventDescription | SSOEDESC | char | OPT | NONE |
Description for the Standard Sequence of Events. | ||||
szOverlapPrevSeqProperty | OPSP | char | OPT | NONE |
A property that indicates the Sequence of Event Task overlaps the previous task for the current Sequence of Events. In other words, the
| ||||
mnTaskId | STSKID | MATH_NUMERIC | OPT | NONE |
A unique number that is used to identify a Standard Task within the Demand Flow Manufacturing system. | ||||
mnTaskRepitition | RPQTY | MATH_NUMERIC | OPT | NONE |
A value that indicates the number of times a task will be repeated. The default value is 1.
In Sequence of Events, if this field is changed then
| ||||
szInternalExternal | INTEXT | char | OPT | NONE |
A user defined code (F30L/IE) that determines if the machine setup is internal or external. Valid values are:
' '
Blank
I
Internal
X
External
In
| ||||
szFeederFlag | FEFG | char | OPT | NONE |
A code to indicate a feeder path on a process. A 'Yes' indicates that a feeder path or a number of feeder paths are associated with the
| ||||
mnFeederPathID | FDPID | MATH_NUMERIC | OPT | NONE |
A number that uniquely identifies a Feeder Path.
In Sequence of Event, if this field is changed then the changes will not be carried over to
| ||||
mnFeederPartNumber | FDITM | MATH_NUMERIC | OPT | NONE |
Part number used in the feeder process which goes to the assembly of the final product.
In Sequence of Event, if this field is changed then
| ||||
szUserReservedCode | URCD | char | OPT | NONE |
This is a 2 position code that is reserved for the user. JDE does not currently use this field and will not utilize this field in the future. | ||||
jdUserReservedDate | URDT | JDEDATE | OPT | NONE |
This is a 6 position code that is reserved for the user. JDE does not currently use this field and will not utilize this field in the future. | ||||
mnUserReservedAmount | URAT | MATH_NUMERIC | OPT | NONE |
This is a 15 position code that is reserved for the user. JDE does not currently use this field and will not utilize this field in the future. | ||||
mnUserReservedNumber | URAB | MATH_NUMERIC | OPT | NONE |
This is a 8 position code that is reserved for the user. JDE does not currently use this field and will not utilize this field in the future. | ||||
szUserReservedReference | URRF | char | OPT | NONE |
A 15-position reference that is reserved for the user. J.D. Edwards does not currently use this field and does not plan to use it in the future. | ||||
szTransactionOriginator | TORG | char | OPT | NONE |
The person who originally entered the transaction. | ||||
szUserId | USER | char | OPT | NONE |
The code that identifies a user profile. | ||||
szProgramId | PID | char | OPT | NONE |
The number that identifies the batch or interactive program (batch or interactive object). For example, the number of the Sales Order Entry
| ||||
szMachineKey | MKEY | char | OPT | NONE |
The Location or Machine Key indicates the name of the machine on the network (server or workstation). | ||||
UniversalDateUpdated | UUPMJ | INVALID ITEM DATA TYPE: 55 | OPT | NONE |
szErrorMessageID | DTAI | char | OPT | NONE |
A code that identifies and defines a unit of information. It is an alphanumeric code up to 8 characters long that does not allow blanks or
| ||||
szFeederBranch | FDMCU | char | OPT | NONE |
Branch Plant where the feeder activity takes place.
In Sequence of Events, if this field is changed then the changes will not be carried over
|
None |
None |