DF30L180A - FF30L005 DFM Task Master Functional Server
| Parameter Name | Data Item | Data Type | Req/Opt | I/O/Both |
|---|---|---|---|---|
| mnTaskId | STSKID | MATH_NUMERIC | OPT | NONE |
A unique number that is used to identify a Standard Task within the Demand Flow Manufacturing system. | ||||
| szStandardTaskProperty | STSKPRP | char | OPT | NONE |
A property that indicates that the task is a Standard Task. Valid values are: Y Yes, this is a standard task. N No, this is not a standard task. | ||||
| szStandardTaskName | TSKNAME | char | OPT | NONE |
Name that is used to identify a Standard Task or Task within the Demand Flow Manufacturing system.
In Sequence of Event, if this field is
| ||||
| mnScenarioId | FSCID | MATH_NUMERIC | OPT | NONE |
A unique number that is used to identify a scenario within the Demand Flow Manufacturing system. | ||||
| szDescription | DESC | char | OPT | NONE |
A description, remark, name, or address. | ||||
| szTaskDescription | TSKDSC | char | OPT | NONE |
Description of a Task that describes the work steps that occur repeatedly across multiple products and/or processes.
In Sequence of
| ||||
| szWorkType | WRKTY | char | OPT | NONE |
A user defined code (F30L/WT), which indicates the type of work being performed. Valid Values are:
RQ - Required - Required
| ||||
| szValueAdded | VALADD | char | OPT | NONE |
A property, which indicates if the task being performed adds value to the end product. Valid values are:
Y - Yes
N - No
In Sequence of
| ||||
| mnResourceID | DFRID | MATH_NUMERIC | OPT | NONE |
A unique value that indicates the Resource ID. In Sequence of Events, if this field is changed then the changes will be carried over to the
| ||||
| szResourceName | DFRDESC | char | OPT | NONE |
A name that describes a resource. This name must be unique within the scenario. In Sequence of Events, if this field is changed, then the
| ||||
| szResourceType | DFRT | char | OPT | NONE |
A value that indicates the type of resource. | ||||
| mnStaticQuantity | STQTY | MATH_NUMERIC | OPT | NONE |
When work content is performed once every "n" times in the process of manufacturing a product, you define a Static Quantity. Static
| ||||
| mnTaskTime | STSKTIME | MATH_NUMERIC | OPT | NONE |
Amount of time required to perform the work of the task.
In Sequence of Events, if this field is changed then the changes will not be carried
| ||||
| cTimeUOM | TIMEUOM | char | OPT | NONE |
A user defined code (F30L/WC) that defines what unit of measure in which the time is defined; such as, Hour, Minutes or Seconds. Valid
| ||||
| szTQCDescription | TQCDESC | char | OPT | NONE |
Instructions used to describe how the TQC work is performed.
In Sequence of Event, if this field is changed then the changes will not be
| ||||
| szTQCCriteria | TQCCRT | char | OPT | NONE |
Value which indicates the criteria for quality control of the work being performed. Value will default to Failsafe. Valid Values are:
FS -
| ||||
| szUserReservedCode | URCD | char | OPT | NONE |
This is a 2 position code that is reserved for the user. JDE does not currently use this field and will not utilize this field in the future. | ||||
| jdUserReservedDate | URDT | JDEDATE | OPT | NONE |
This is a 6 position code that is reserved for the user. JDE does not currently use this field and will not utilize this field in the future. | ||||
| mnUserReservedAmount | URAT | MATH_NUMERIC | OPT | NONE |
This is a 15 position code that is reserved for the user. JDE does not currently use this field and will not utilize this field in the future. | ||||
| mnUserReservedNumber | URAB | MATH_NUMERIC | OPT | NONE |
This is a 8 position code that is reserved for the user. JDE does not currently use this field and will not utilize this field in the future. | ||||
| szUserReservedReference | URRF | char | OPT | NONE |
A 15-position reference that is reserved for the user. J.D. Edwards does not currently use this field and does not plan to use it in the future. | ||||
| szProgramId | PID | char | OPT | NONE |
The number that identifies the batch or interactive program (batch or interactive object). For example, the number of the Sales Order Entry
| ||||
| cSuppressErrorMessage | SUPPS | char | OPT | NONE |
A flag indicating whether or not runtime error messaging will occur when an error message is issued from a business function.
0 = allow
| ||||
| cErrorCode | ERRC | char | OPT | NONE |
This error code indicates if any errors occurred during the creation of the Trip Document Detail (F4914) records by the Delivery Document
| ||||
| szErrorMessageID | DTAI | char | OPT | NONE |
A code that identifies and defines a unit of information. It is an alphanumeric code up to 8 characters long that does not allow blanks or
| ||||
| cActionCode | ACTN | char | OPT | NONE |
A code that specifies the action that is performed. Valid values are: A Add C Change | ||||
| mnTaskTimeInSeconds | STSKTIME | MATH_NUMERIC | OPT | NONE |
Amount of time required to perform the work of the task.
In Sequence of Events, if this field is changed then the changes will not be carried
| ||||
| None |
| None |