AddScenarioEX

Scenario Master Public Interface

Minor Business Rule

Object Name: BF30L111

Parent DLL: CDFM

Location: Client/Server

Language: C

Data Structure

DF30L111A - Add Scenario EX

Parameter NameData ItemData TypeReq/OptI/O/Both
mnScenarioIdFSCIDMATH_NUMERICOPTBOTH

A unique number that is used to identify a scenario within the Demand Flow Manufacturing system.

szScenarioNameSCEDESCcharOPTINPUT

A user defined name for the scenario.

cScenarioStatusACTSCcharOPTINPUT

A flag used to identify the status of the scenario.

szScenarioUOMSCUOMcharOPTINPUT

A unit of measure for the scenario

szProgramIdPIDcharOPTINPUT

The number that identifies the batch or interactive program (batch or interactive object). For example, the number of the Sales Order Entry 
interactive program is P4210, and the number of the Print Invoices batch process report is R42565. The program ID is a variable length value. 
It is assigned according to a structured syntax in the form TSSXXX, where: T The first character of the number is alphabetic and identifies the 
type, such as P for Program, R for Report, and so on. For example, the value P in the number P4210 indicates that the object is a 
program. SS The second and third characters of the number are numeric and identify the system code. For example, the value 42 in the number P4210 
indicates that this program belongs to system 42, which is the Sales Order Processing system. XXX The remaining characters of the numer are 
numeric and identify a unique program or report. For example, the value 10 in the number P4210 indicates that this is the Sales Order Entry 
program.

szUserReservedCodeURCDcharOPTNONE

This is a 2 position code that is reserved for the user.  JDE does not currently use this field and will not utilize this field in the future.

jdUserReservedDateURDTJDEDATEOPTNONE

This is a 6 position code that is reserved for the user.  JDE does not currently use this field and will not utilize this field in the future.

mnUserReservedAmountURATMATH_NUMERICOPTNONE

This is a 15 position code that is reserved for the user.  JDE does not currently use this field and will not utilize this field in the future.

mnUserReservedNumberURABMATH_NUMERICOPTNONE

This is a 8 position code that is reserved for the user.  JDE does not currently use this field and will not utilize this field in the future.

szUserReservedReferenceURRFcharOPTNONE

A 15-position reference that is reserved for the user.  J.D. Edwards does not currently use this field and does not plan to use it in the future.

cSuppressErrorMessageSUPPScharOPTINPUT

A flag indicating whether or not runtime error messaging will occur when an error message is issued from a business function.        0 = allow 
runtime error message handling.        1 = suppress runtime error message handling.

cErrorCodeERRCcharOPTOUTPUT

This error code indicates if any errors occurred during the creation of the Trip Document Detail (F4914) records by the Delivery Document 
Set Server program (XT4914).

szErrorMessageIDDTAIcharOPTNONE

A code that identifies and defines a unit of information. It is an alphanumeric code up to 8 characters long that does not allow blanks or 
special characters such as %, &, or +. You create new data items using system codes 55-59. You cannot change the alias.

cDFIntegrationWithMfgDFINTGcharOPTNONE

A flag that indicates if DFM is integrated with Manufacturing Management. 

Related Functions

None

Related Tables

None
DeleteScenarioEX

DeleteScenarioEX

Scenario Master Public Interface

Minor Business Rule

Object Name: BF30L111

Parent DLL: CDFM

Location: Client/Server

Language: C

Data Structure

DF30L111C - Delete Scenario EX

Parameter NameData ItemData TypeReq/OptI/O/Both
mnScenarioIdFSCIDMATH_NUMERICOPTINPUT

A unique number that is used to identify a scenario within the Demand Flow Manufacturing system.

cSuppressErrorMessageSUPPScharOPTINPUT

A flag indicating whether or not runtime error messaging will occur when an error message is issued from a business function.        0 = allow 
runtime error message handling.        1 = suppress runtime error message handling.

cErrorCodeERRCcharOPTOUTPUT

This error code indicates if any errors occurred during the creation of the Trip Document Detail (F4914) records by the Delivery Document 
Set Server program (XT4914).

szErrorMessageIDDTAIcharOPTNONE

A code that identifies and defines a unit of information. It is an alphanumeric code up to 8 characters long that does not allow blanks or 
special characters such as %, &, or +. You create new data items using system codes 55-59. You cannot change the alias.

Related Functions

None

Related Tables

None
RetrieveActiveScenarioEX

RetrieveActiveScenarioEX

Scenario Master Public Interface

Minor Business Rule

Object Name: BF30L111

Parent DLL: CDFM

Location: Client/Server

Language: C

Data Structure

DF30L111E - Retrieve Active Scenario EX

Parameter NameData ItemData TypeReq/OptI/O/Both
mnScenarioIdFSCIDMATH_NUMERICOPTOUTPUT

A unique number that is used to identify a scenario within the Demand Flow Manufacturing system.

szScenarioNameSCEDESCcharOPTOUTPUT

A user defined name for the scenario.

cScenarioStatusACTSCcharOPTOUTPUT

A flag used to identify the status of the scenario.

szScenarioUOMSCUOMcharOPTOUTPUT

A unit of measure for the scenario

cSuppressErrorMessageSUPPScharOPTINPUT

A flag indicating whether or not runtime error messaging will occur when an error message is issued from a business function.        0 = allow 
runtime error message handling.        1 = suppress runtime error message handling.

cErrorCodeERRCcharOPTOUTPUT

This error code indicates if any errors occurred during the creation of the Trip Document Detail (F4914) records by the Delivery Document 
Set Server program (XT4914).

szErrorMessageIDDTAIcharOPTNONE

A code that identifies and defines a unit of information. It is an alphanumeric code up to 8 characters long that does not allow blanks or 
special characters such as %, &, or +. You create new data items using system codes 55-59. You cannot change the alias.

cDFIntegrationWithMfgDFINTGcharOPTNONE

A flag that indicates if DFM is integrated with Manufacturing Management. 

Related Functions

None

Related Tables

None
RetrieveVerifyScenarioEX

RetrieveVerifyScenarioEX

Scenario Master Public Interface

Minor Business Rule

Object Name: BF30L111

Parent DLL: CDFM

Location: Client/Server

Language: C

Data Structure

DF30L111B - Verify and Retrieve Scenario Master EX

Parameter NameData ItemData TypeReq/OptI/O/Both
mnScenarioIdFSCIDMATH_NUMERICOPTINPUT

A unique number that is used to identify a scenario within the Demand Flow Manufacturing system.

szScenarioNameSCEDESCcharOPTOUTPUT

A user defined name for the scenario.

cScenarioStatusACTSCcharOPTOUTPUT

A flag used to identify the status of the scenario.

szScenarioUOMSCUOMcharOPTOUTPUT

A unit of measure for the scenario

cSuppressErrorMessageSUPPScharOPTINPUT

A flag indicating whether or not runtime error messaging will occur when an error message is issued from a business function.        0 = allow 
runtime error message handling.        1 = suppress runtime error message handling.

cErrorCodeERRCcharOPTOUTPUT

This error code indicates if any errors occurred during the creation of the Trip Document Detail (F4914) records by the Delivery Document 
Set Server program (XT4914).

szErrorMessageIDDTAIcharOPTNONE

A code that identifies and defines a unit of information. It is an alphanumeric code up to 8 characters long that does not allow blanks or 
special characters such as %, &, or +. You create new data items using system codes 55-59. You cannot change the alias.

cDFIntegrationWithMfgDFINTGcharOPTNONE

A flag that indicates if DFM is integrated with Manufacturing Management. 

Related Functions

None

Related Tables

None
UpdateScenarioEX

UpdateScenarioEX

Scenario Master Public Interface

Minor Business Rule

Object Name: BF30L111

Parent DLL: CDFM

Location: Client/Server

Language: C

Data Structure

DF30L111D - Update Scenario EX

Parameter NameData ItemData TypeReq/OptI/O/Both
mnScenarioIdFSCIDMATH_NUMERICOPTINPUT

A unique number that is used to identify a scenario within the Demand Flow Manufacturing system.

szScenarioNameSCEDESCcharOPTINPUT

A user defined name for the scenario.

cScenarioStatusACTSCcharOPTINPUT

A flag used to identify the status of the scenario.

szScenarioUOMSCUOMcharOPTINPUT

A unit of measure for the scenario

szProgramIdPIDcharOPTINPUT

The number that identifies the batch or interactive program (batch or interactive object). For example, the number of the Sales Order Entry 
interactive program is P4210, and the number of the Print Invoices batch process report is R42565. The program ID is a variable length value. 
It is assigned according to a structured syntax in the form TSSXXX, where: T The first character of the number is alphabetic and identifies the 
type, such as P for Program, R for Report, and so on. For example, the value P in the number P4210 indicates that the object is a 
program. SS The second and third characters of the number are numeric and identify the system code. For example, the value 42 in the number P4210 
indicates that this program belongs to system 42, which is the Sales Order Processing system. XXX The remaining characters of the numer are 
numeric and identify a unique program or report. For example, the value 10 in the number P4210 indicates that this is the Sales Order Entry 
program.

szUserReservedCodeURCDcharOPTNONE

This is a 2 position code that is reserved for the user.  JDE does not currently use this field and will not utilize this field in the future.

jdUserReservedDateURDTJDEDATEOPTNONE

This is a 6 position code that is reserved for the user.  JDE does not currently use this field and will not utilize this field in the future.

mnUserReservedAmountURATMATH_NUMERICOPTNONE

This is a 15 position code that is reserved for the user.  JDE does not currently use this field and will not utilize this field in the future.

mnUserReservedNumberURABMATH_NUMERICOPTNONE

This is a 8 position code that is reserved for the user.  JDE does not currently use this field and will not utilize this field in the future.

szUserReservedReferenceURRFcharOPTNONE

A 15-position reference that is reserved for the user.  J.D. Edwards does not currently use this field and does not plan to use it in the future.

cSuppressErrorMessageSUPPScharOPTINPUT

A flag indicating whether or not runtime error messaging will occur when an error message is issued from a business function.        0 = allow 
runtime error message handling.        1 = suppress runtime error message handling.

cErrorCodeERRCcharOPTOUTPUT

This error code indicates if any errors occurred during the creation of the Trip Document Detail (F4914) records by the Delivery Document 
Set Server program (XT4914).

szErrorMessageIDDTAIcharOPTNONE

A code that identifies and defines a unit of information. It is an alphanumeric code up to 8 characters long that does not allow blanks or 
special characters such as %, &, or +. You create new data items using system codes 55-59. You cannot change the alias.

cDFIntegrationWithMfgDFINTGcharOPTNONE

A flag that indicates if DFM is integrated with Manufacturing Management. 

Related Functions

None

Related Tables

None