ClearCacheABLocalizedData_74

Address Book Localized Data - COMM - 01

Minor Business Rule

Object Name: B7410001

Parent DLL: CLOC

Location: Client/Server

Language: C

Data Structure

D7410001G - Clear Cache Address Book Localized Data - COMM - 01

Parameter NameData ItemData TypeReq/OptI/O/Both
mnAddressNumberAN8MATH_NUMERICOPTINPUT

A number that identifies an entry in the Address Book system, such as employee, applicant, participant, customer, supplier, tenant, or 
location.

szErrorCodeDTAIcharOPTOUTPUT

A code that identifies and defines a unit of information. It is an alphanumeric code up to 8 characters long that does not allow blanks or 
special characters such as %, &, or +. You create new data items using system codes 55-59. You cannot change the alias.

cSuppressErrorMessageSUPPScharOPTINPUT

A flag indicating whether or not runtime error messaging will occur when an error message is issued from a business function.        0 = allow 
runtime error message handling.        1 = suppress runtime error message handling.

Related Functions

B9800100 Get Audit Information

Related Tables

F741001T Address Book Tag File - COMM - 01
DeleteABLocalizedData_74

DeleteABLocalizedData_74

Address Book Localized Data - COMM - 01

Minor Business Rule

Object Name: B7410001

Parent DLL: CLOC

Location: Client/Server

Language: C

Data Structure

D7410001E - Delete Address Book Localized Data - COMM - 01

Parameter NameData ItemData TypeReq/OptI/O/Both
mnAddressNumberAN8MATH_NUMERICOPTINPUT

A number that identifies an entry in the Address Book system, such as employee, applicant, participant, customer, supplier, tenant, or 
location.

szErrorCodeDTAIcharOPTOUTPUT

A code that identifies and defines a unit of information. It is an alphanumeric code up to 8 characters long that does not allow blanks or 
special characters such as %, &, or +. You create new data items using system codes 55-59. You cannot change the alias.

cSuppressErrorMessageSUPPScharOPTINPUT

A flag indicating whether or not runtime error messaging will occur when an error message is issued from a business function.        0 = allow 
runtime error message handling.        1 = suppress runtime error message handling.

Related Functions

B9800100 Get Audit Information

Related Tables

F741001T Address Book Tag File - COMM - 01
EditABLocalizedData_74

EditABLocalizedData_74

Address Book Localized Data - COMM - 01

Minor Business Rule

Object Name: B7410001

Parent DLL: CLOC

Location: Client/Server

Language: C

Data Structure

D7410001F - Edit Address Book Localized Data - COMM - 01

Parameter NameData ItemData TypeReq/OptI/O/Both
mnAddressNumberAN8MATH_NUMERICOPTINPUT

A number that identifies an entry in the Address Book system, such as employee, applicant, participant, customer, supplier, tenant, or 
location.

szErrorCodeDTAIcharOPTOUTPUT

A code that identifies and defines a unit of information. It is an alphanumeric code up to 8 characters long that does not allow blanks or 
special characters such as %, &, or +. You create new data items using system codes 55-59. You cannot change the alias.

cSuppressErrorMessageSUPPScharOPTINPUT

A flag indicating whether or not runtime error messaging will occur when an error message is issued from a business function.        0 = allow 
runtime error message handling.        1 = suppress runtime error message handling.

Related Functions

B9800100 Get Audit Information

Related Tables

F741001T Address Book Tag File - COMM - 01
EditCacheABLocalizedData_74

EditCacheABLocalizedData_74

Address Book Localized Data - COMM - 01

Minor Business Rule

Object Name: B7410001

Parent DLL: CLOC

Location: Client/Server

Language: C

Data Structure

D7410001B - Edit Cache Address Book Localized Data - COMM - 01

Parameter NameData ItemData TypeReq/OptI/O/Both
mnAddressNumberAN8MATH_NUMERICOPTINPUT

A number that identifies an entry in the Address Book system, such as employee, applicant, participant, customer, supplier, tenant, or 
location.

szVATConditionK74VCcharOPTBOTH

A code that identifies the registration condition about Value Added Tax (V.A.T.).

szErrorCodeDTAIcharOPTOUTPUT

A code that identifies and defines a unit of information. It is an alphanumeric code up to 8 characters long that does not allow blanks or 
special characters such as %, &, or +. You create new data items using system codes 55-59. You cannot change the alias.

cSuppressErrorMessageSUPPScharOPTINPUT

A flag indicating whether or not runtime error messaging will occur when an error message is issued from a business function.        0 = allow 
runtime error message handling.        1 = suppress runtime error message handling.

Related Functions

B9800100 Get Audit Information

Related Tables

F741001T Address Book Tag File - COMM - 01
GetABLocalizedDataFromCache_74

GetABLocalizedDataFromCache_74

Address Book Localized Data - COMM - 01

Minor Business Rule

Object Name: B7410001

Parent DLL: CLOC

Location: Client/Server

Language: C

Data Structure

D7410001A - Get Address Book Localized Data From Cache - COMM - 01

Parameter NameData ItemData TypeReq/OptI/O/Both
mnAddressNumberAN8MATH_NUMERICOPTINPUT

A number that identifies an entry in the Address Book system, such as employee, applicant, participant, customer, supplier, tenant, or 
location.

szVATConditionK74VCcharOPTOUTPUT

A code that identifies the registration condition about Value Added Tax (V.A.T.).

szErrorCodeDTAIcharOPTOUTPUT

A code that identifies and defines a unit of information. It is an alphanumeric code up to 8 characters long that does not allow blanks or 
special characters such as %, &, or +. You create new data items using system codes 55-59. You cannot change the alias.

cSuppressErrorMessageSUPPScharOPTINPUT

A flag indicating whether or not runtime error messaging will occur when an error message is issued from a business function.        0 = allow 
runtime error message handling.        1 = suppress runtime error message handling.

Related Functions

B9800100 Get Audit Information

Related Tables

F741001T Address Book Tag File - COMM - 01
SaveABLocalizedDataToCache_74

SaveABLocalizedDataToCache_74

Address Book Localized Data - COMM - 01

Minor Business Rule

Object Name: B7410001

Parent DLL: CLOC

Location: Client/Server

Language: C

Data Structure

D7410001C - Save Address Book Localized Data To Cache - COMM - 01

Parameter NameData ItemData TypeReq/OptI/O/Both
mnAddressNumberAN8MATH_NUMERICOPTINPUT

A number that identifies an entry in the Address Book system, such as employee, applicant, participant, customer, supplier, tenant, or 
location.

szVATConditionK74VCcharOPTINPUT

A code that identifies the registration condition about Value Added Tax (V.A.T.).

szErrorCodeDTAIcharOPTOUTPUT

A code that identifies and defines a unit of information. It is an alphanumeric code up to 8 characters long that does not allow blanks or 
special characters such as %, &, or +. You create new data items using system codes 55-59. You cannot change the alias.

cSuppressErrorMessageSUPPScharOPTINPUT

A flag indicating whether or not runtime error messaging will occur when an error message is issued from a business function.        0 = allow 
runtime error message handling.        1 = suppress runtime error message handling.

Related Functions

B9800100 Get Audit Information

Related Tables

F741001T Address Book Tag File - COMM - 01
SaveCacheABLocDataToTable_74

SaveCacheABLocDataToTable_74

Address Book Localized Data - COMM - 01

Minor Business Rule

Object Name: B7410001

Parent DLL: CLOC

Location: Client/Server

Language: C

Data Structure

D7410001D - Save Cache Address Book Localized Data To Table - COMM - 01

Parameter NameData ItemData TypeReq/OptI/O/Both
mnAddressNumberAN8MATH_NUMERICOPTINPUT

A number that identifies an entry in the Address Book system, such as employee, applicant, participant, customer, supplier, tenant, or 
location.

szErrorCodeDTAIcharOPTOUTPUT

A code that identifies and defines a unit of information. It is an alphanumeric code up to 8 characters long that does not allow blanks or 
special characters such as %, &, or +. You create new data items using system codes 55-59. You cannot change the alias.

cSuppressErrorMessageSUPPScharOPTINPUT

A flag indicating whether or not runtime error messaging will occur when an error message is issued from a business function.        0 = allow 
runtime error message handling.        1 = suppress runtime error message handling.

Related Functions

B9800100 Get Audit Information

Related Tables

F741001T Address Book Tag File - COMM - 01