D3202080 - F3291ConfiguratorCache
Parameter Name | Data Item | Data Type | Req/Opt | I/O/Both |
---|---|---|---|---|
cCacheActionCode | EV01 | char | OPT | NONE |
An option that specifies the type of processing for an event. | ||||
cCacheCodeError | EV01 | char | OPT | NONE |
An option that specifies the type of processing for an event. | ||||
cRecordFoundInTable | EV01 | char | OPT | NONE |
An option that specifies the type of processing for an event. | ||||
cReturnCursor | EV01 | char | OPT | NONE |
An option that specifies the type of processing for an event. | ||||
cSuppressErrorMessage | SUPPS | char | OPT | NONE |
A flag indicating whether or not runtime error messaging will occur when an error message is issued from a business function.
0 = allow
| ||||
szErrorMessageID | DTAI | char | OPT | NONE |
A code that identifies and defines a unit of information. It is an alphanumeric code up to 8 characters long that does not allow blanks or
| ||||
idCursor | GENLNG | ID | OPT | NONE |
General purpose ID variable. | ||||
nIndexNumber | INT01 | integer | OPT | NONE |
Number of Days in Future to Query for Responses Due. | ||||
nNumberOfKeys | INT01 | integer | OPT | NONE |
Number of Days in Future to Query for Responses Due. | ||||
mnJobNumber | JOBS | MATH_NUMERIC | OPT | NONE |
The job number (work station ID) which executed the particular job. | ||||
mnItemNumberShortKit | KIT | MATH_NUMERIC | OPT | NONE |
The system provides for three separate item numbers.
1. Item Number (short) - An eight-digit, computer assigned, completely
| ||||
szIdentifier2ndItem | LITM | char | OPT | NONE |
A number that identifies the item. The system provides three separate item numbers plus an extensive cross-reference capability to
| ||||
szIdentifier3rdItem | AITM | char | OPT | NONE |
The system provides three separate item numbers plus an extensive cross-reference capability to alternate item numbers. These item
| ||||
szBranchPlant | MCU | char | OPT | NONE |
An alphanumeric code that identifies a separate entity within a business for which you want to track costs. For example, a business unit
| ||||
mnParentSegmentNumber | PEL | MATH_NUMERIC | OPT | NONE |
A number that establishes the sequence in which the segments were defined in the system. Segment numbers are user
| ||||
jdEffectiveFromDate | EFFF | JDEDATE | OPT | NONE |
A date that indicates one of the following:
o When a component part goes into effect on a bill of material
o When a routing step goes into
| ||||
jdEffectiveThruDate | EFFT | JDEDATE | OPT | NONE |
A date that indicates one of the following:
o When a component part is no longer in effect on a bill of material
o When a routing step is no
| ||||
szDescriptionLine | DSC1 | char | OPT | NONE |
Brief information about an item; a remark or an explanation. | ||||
szCommonAtribute | DTAI | char | OPT | NONE |
A code that identifies and defines a unit of information. It is an alphanumeric code up to 8 characters long that does not allow blanks or
| ||||
cRequiredToBe | ATRQ | char | OPT | NONE |
A code that specifies whether a segment is required or optional in a configuration, or whether the system must calculate it to specification
| ||||
szProductCode | SY | char | OPT | NONE |
A user defined code (98/SY) that identifies a system. Valid values include:
01
Address Book
03B
Accounts Receivable
04
Accounts
| ||||
szUserDefinedCodes | RT | char | OPT | NONE |
A code that identifies the table that contains user defined codes. The table is also referred to as a UDC type. | ||||
szValueForEntryDefault | DVAL | char | OPT | NONE |
Used as the initial value on the data entry screen for the associated data item. The value entered must be the exact same length as the
| ||||
szLowerAllowedValue | LVAL | char | OPT | NONE |
The lower allowed value of this specific segment. If you enter a value here,then you must also enter an upper allowed value. | ||||
szAllowedValueUpper | UVAL | char | OPT | NONE |
The upper allowed value of this specific segment. If you enter a value here,then you must also enter an lower allowed value. | ||||
cNumericYN | CNUM | char | OPT | NONE |
Determines whether a user defined code is numeric or alphanumeric.
Valid values are:
Y Indicates that the code is numeric and should be
| ||||
mnDisplayOrder | DTAS | MATH_NUMERIC | OPT | NONE |
The field size of the data item.
Note: All amount fields should be entered as 15 bytes, 0 decimals, and the data item type should be P
| ||||
cDataDisplayDecimals | CDEC | char | OPT | NONE |
A value that designates the number of decimals in the currency, amount, or quantity fields the system displays. For example, U.S. Dollars
| ||||
cSaveSegment | ATSA | char | OPT | NONE |
A user defined code (32/YN) that specifices whether the segment value is significant enough to make the configuration unique. Valid values
| ||||
mnSpacesBeforeSegmentInfor | SPBN | MATH_NUMERIC | OPT | NONE |
The number of spaces that should print before the segment information in the user defined format. | ||||
cPrintSegmentNumber | ATSN | char | OPT | NONE |
A user defined code (32/YN) that specifies whether the system prints the segment number on the order paperwork. Valid values are:
0
Do
| ||||
cPrintSegmentDescription | ATSD | char | OPT | NONE |
A user defined code (32/YN) that specifies whether the system prints the segment description on the order paperwork. Valid values
| ||||
cPrintSegmentValue | ATSV | char | OPT | NONE |
A user defined code (32/YN) that specifies whether the system prints the segment value on the order paperwork. Valid values are:
0
Do not
| ||||
cPrintSegmentValueDesc | ATVD | char | OPT | NONE |
A user defined code (32/YN) that specifies whether the system prints the segment value description on the order paperwork. Valid values
| ||||
mnSpacesAfterSegmentInform | SPAN | MATH_NUMERIC | OPT | NONE |
The number of spaces that should print after the segment information in the user defined format. | ||||
cReturnandStartNewLine | RTNL | char | OPT | NONE |
A user defined code (32/YN) that indicates whether the system starts a new line after it prints the segment nformation. Valid values
| ||||
cDerivedCalculationRound | RNDC | char | OPT | NONE |
This field will be used to indicate how many positions to the right of the decimal a derived calculation should be rounded.
For example,
o If
| ||||
szUpdateCategoryCode | UPCC | char | OPT | NONE |
A code that specifies which work order category code that the system populates with the segment value during order entry. | ||||
szUserReservedCode | URCD | char | OPT | NONE |
This is a 2 position code that is reserved for the user. JDE does not currently use this field and will not utilize this field in the future. | ||||
jdUserReservedDate | URDT | JDEDATE | OPT | NONE |
This is a 6 position code that is reserved for the user. JDE does not currently use this field and will not utilize this field in the future. | ||||
mnUserReservedAmount | URAT | MATH_NUMERIC | OPT | NONE |
This is a 15 position code that is reserved for the user. JDE does not currently use this field and will not utilize this field in the future. | ||||
mnUserReservedNumber | URAB | MATH_NUMERIC | OPT | NONE |
This is a 8 position code that is reserved for the user. JDE does not currently use this field and will not utilize this field in the future. | ||||
szUserReservedReference | URRF | char | OPT | NONE |
A 15-position reference that is reserved for the user. J.D. Edwards does not currently use this field and does not plan to use it in the future. | ||||
szUserId | USER | char | OPT | NONE |
The code that identifies a user profile. | ||||
szProgramId | PID | char | OPT | NONE |
The number that identifies the batch or interactive program (batch or interactive object). For example, the number of the Sales Order Entry
| ||||
szWorkStationId | JOBN | char | OPT | NONE |
The code that identifies the work station ID that executed a particular job. | ||||
jdDateUpdated | UPMJ | JDEDATE | OPT | NONE |
The date that specifies the last update to the file record. | ||||
mnTimeOfDay | TDAY | MATH_NUMERIC | OPT | NONE |
The computer clock in hours:minutes:seconds. |
None |
None |