F32922VerifyAndGetRangeRow

F32922 Verify And Get Range Row

Minor Business Rule

Object Name: B3200270

Parent DLL: CMFG

Location: Client/Server

Language: C

1.Functional Description
This business function will validate that a Range Exisits for the given key.

1.1Purpose


1.2Setup Notes and Prerequisites

1.3Special Logic


2.Technical Specifications


2.4Processing 

1. Get the row (F32921) using KIT, MCU,ATOS and ATO_1,FCOD as partial Key. Return vl01, vl02

^

Data Structure

D3200270 - F32922 Verify And Get Range Row

Parameter NameData ItemData TypeReq/OptI/O/Both
cFileCodeFCODcharNONENONE

The file code is used in the *RANGE and *VALUE file for configurations to determine if the *RANGE or *VALUE goes with a "IF" statement, a 
"THEN"statement or with an assembly inclusion rule statement.

szBranchMCUcharNONENONE

An alphanumeric code that identifies a separate entity within a business for which you want to track costs. For example, a business unit 
might be a warehouse location, job, project, work center, branch, or plant. You can assign a business unit to a document, entity, or person for 
purposes of responsibility reporting. For example, the system provides reports of open accounts payable and accounts receivable by 
business unit to track equipment by responsible department. Business unit security might prevent you from viewing information about business units 
for which you have no authority.

mnParentItemKITMATH_NUMERICNONENONE

The system provides for three separate item numbers.    1.   Item Number (short) - An eight-digit, computer assigned, completely 
non-significant item number.    2.   2nd Item Number - The 25-digit, free form, user defined alphanumeric item number.    3.   3rd Item Number - Another 
25-digit, free form, user defined alphanumeric item number.

mnRuleNumberATO#MATH_NUMERICNONENONE

The number associated with a set of cross-segment editing rules or assembly inclusion rules.

mnSequenceNumberATOSMATH_NUMERICNONENONE

The Sequence number is the rule number within an edit group of cross-segment editing rules or assembly inclusion rules. You can insert a 
line within a rule to assign a new sequence number.

szErrorMessageIDDTAIcharNONENONE

A code that identifies and defines a unit of information. It is an alphanumeric code up to 8 characters long that does not allow blanks or 
special characters such as %, &, or +. You create new data items using system codes 55-59. You cannot change the alias.

cSuppressErrorMessageEV01charNONENONE

An option that specifies the type of processing for an event.

szFromValueSRFVcharOPTNONE

The starting value of a range of numbers. In configurator, the *Range variable is used in the Values field associated with the cross-segment 
editing rules and assembly inclusion rules. Entering *Range in this field accesses the Range Revision (From Range and To Range) form. 
The *Range values represent answers to the segment referenced by the rule. You can use a UDC table to act as a filter to narrow the 
possible valid values that the logic statement will return.

szThruValueSRTVcharOPTNONE

The ending value of a range of numbers. In configurator, the *Range variable is used in the Values field associated with the cross-segment 
editing rules and assembly inclusion rules. Entering *Range in this field accesses the Range Revision (From Range and To Range) form. 
The *Range values represent answers to the segment referenced by the rule. You can use a UDC table to act as a filter to narrow the possible 
valid values that the logic statement will return.

Related Functions

None

Related Tables

F32922 Cross Segment Editing Rules - Range